Material Safety
Data Sheet
May be used to Comply with OSHA’s Hazard Communication Standard, 29 CFR 1910.1200. Standard must be Consulted for specific requirements |
HMIS |
||||||||||||
HEALTH 1 REACTIVITY 1 |
|||||||||||||
FLAMMABILITY 2 PERSONAL PROTECTION A |
|||||||||||||
|
Identity (As Used On Label
and List) A1072 Waterfall Mist |
Note: Blank spaces are not permitted. If any item is not applicable, or no
information is available, the space must be marked to indicate that.
|
||||||||||||
Section I
|
|||||||||||||
|
Manufactured for: OMEGA
INDUSTRIAL SUPPLY, INC |
Emergency Telephone Number: 1-800-424-9300 |
||||||||||||
|
Address (Number, Street,
City, State, and Zip Code) 4950
Fulton Dr Ste B |
Telephone Number for
Information: 1-800-571-7347 |
||||||||||||
|
Fairfield,
CA 94534 |
Date Prepared
07-29-2004 |
||||||||||||
|
|
Signature of Prepare
(Optional) REGULATORY
DEPT. |
||||||||||||
|
Section II -
Hazardous Ingredients / Identity Information |
|||||||||||||
|
Hazardous
Components (Specific
Chemical Identity, Common Name(s)) |
CAS No. |
OSHA PEL |
ACGIH-TLV |
Other Limits Recommended. |
%(Opt.) |
||||||||
|
Acetone |
67-64-1 |
1000 ppm |
750 ppm |
N/A |
|
||||||||
|
Isoparafinic Hydrocarbon |
64742-47-8 |
400 ppm |
400 ppm |
|
|
||||||||
|
Propane/Isobutane* |
74-98-6 |
1000 ppm |
N/A |
N/A |
|
||||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
||||||||
|
|
|||||||||||||
|
This product contains the toxic chemicals marked with (*) subject to the reporting requiring under SARA Title III Section 313. |
|||||||||||||
|
of the emergency planning and community right-to-know act of 1986 and of 40CFR372. |
|||||||||||||
|
|
|||||||||||||
|
Any substance listed as hazardous by the State of California, Florida, Illinois, Michigan, New Jersey, Ohio, Pennsylvania or |
|||||||||||||
|
Texas is described above if known present in regulated concentrations. |
|||||||||||||
|
|
|||||||||||||
Section III -
Physical Chemical Characteristics
|
|||||||||||||
|
Boiling Point |
180ºF |
Specific Gravity (H2O
= 1) Concentrate |
0.79 |
||||||||||
|
Vapor Pressure
(mm/hg) |
33 |
VOC % Content |
30% |
||||||||||
|
Vapor Density
(Air=1) |
>1 |
Evaporation Rate
(Butyl Acetate = 1) |
1 |
||||||||||
|
Solubility in Water |
NIL |
pH |
|
||||||||||
|
Appearance and Odor—Clear spray, floral scent |
|||||||||||||
Section IV –
Fire and Explosion Hazard Data
|
|||||||||||||
|
USA Flame Projection Test
(ASTM D-3065) |
Flammable Limits |
LEL |
UEL |
||||||||||
|
<100ºF TCC |
|
N/A |
N/A |
||||||||||
Extinguishing Media – Standard dry chemical fire extinguisher
|
|||||||||||||
|
Special Fire
Fighting Procedures – Wear self-contained breathing apparatus whenever indicated. |
|||||||||||||
|
Unusual Fire and Explosion Hazards –
Flammable. Contents under
pressure. Exposure to temperatures
above 120ºF may cause bursting. |
|||||||||||||
Page 2 of 2 for A1072 Waterfall Mist
Section V –
Reactivity Data
|
||||||||||||
|
Stability |
Unstable |
Conditions to
Avoid – Temperatures 120ºF |
||||||||||
|
|
||||||||||||
|
Incompatibility (Materials
to Avoid) – None |
||||||||||||
|
Hazardous Decomposition or Byproducts –None |
||||||||||||
|
Hazardous Polymerization |
May Occur |
Conditions to
Avoid – None |
||||||||||
|
Will Not
Occur |
|
|||||||||||
Section VI –
Health Hazard Data
|
||||||||||||
Route(s) of
Entry:
|
Eyes? Yes |
Inhalation?
Yes
|
Skin?
Yes
|
Ingestion?
No
|
||||||||
|
Health Hazards (Acute and
Chronic) – Inhalation — Excessive exposure may cause slight
dizziness. Eyes — Strong irritation reddening Skin — Mild irritation. |
||||||||||||
Carcinogenicity:
|
NTP?
|
IARC Monographs?
|
OSHA Regulated?
|
|||||||||
|
|
No
|
No
|
No
|
|||||||||
|
Signs and
symptoms of Exposure: See Above |
||||||||||||
|
Medical Conditions Generally Aggravated –None
Known |
||||||||||||
|
Emergency and
First Aid Procedures. Eyes—Flush with water for 15 minutes. Inhalation—Remove to fresh air Skin —wash with soap and water |
||||||||||||
Section VII –
Precautions For Safe Handling and Use
|
||||||||||||
|
Steps to be
Taken in Case Material is Released or Spilled. Wipe up with rag or se
some absorbent clay material. |
||||||||||||
|
Waste Disposal Method – Dispose
of residue in accordance with federal, state and local regulations. Do not puncture or incinerate
container. Do not reuse
container. Warp container and place
in trash collection |
||||||||||||
|
Precautions
to be Taken in Handling and Storing – Do not use or store near
heat or open flame. Exposure to
temperatures above 120ºF may cause bursting. |
||||||||||||
|
Other Precautions –None |
||||||||||||
Section VIII –
Control Measures
|
||||||||||||
|
Respiratory Protection
(Specify Type) – None |
||||||||||||
|
Ventilation |
Local Exhaust |
Adequate |
Special |
N/A |
||||||||
|
Mechanical
(General) |
N/A |
Other |
N/A |
|||||||||
|
Protective
Gloves – N/A |
Eye
Protection – Safety glasses are
recommend whenever chemicals are used. |
|||||||||||
|
Other protective Clothing or Equipment – N/A |
||||||||||||
|
Work/Hygienic Practices – Observe good hygiene. Wash hands thoroughly after eating,
drinking, and using restrooms, etc. |
||||||||||||
While the information and recommendations set forth
herein are believed to be accurate as of the date hereon Omega Industrial
Supply Inc. makes no warranty with respect thereto and disclaims all liability
from reliance thereon.